Página 1 - 2012-01-18

Parani-SD1000U User Guide Version 2.0.2 2012-01-18

Página 2 - Technical Support

Figure 2-2 Connecting a Serial Device to Parani-SD1000U 2.2.2. USB Driver Installation Windows XP and later versions already include the USB dr

Página 3 - Revision History

Figure 2-3 USB Driver Installation 2.2.3. Virtual Serial Port The user can use the Parani-SD1000U adapter connected as a virtual serial port aft

Página 4 - Contents

3. Configuration 3.1. Operation Modes In addition to the serial port configurations the Parani-SD1000U also requires some settings for

Página 5 - Appendix B: S-Register 41

3.2. LED Indicators Serial-Tx and Serial-Rx LED will flash accordingly when data is transmitted. For small data transmissions, it may be

Página 6 - Appendix E: Warranty 48

When using hardware flow control, Parani-SD1000U disables RTS so that it stops receiving any further data from the host when the b

Página 7 - 1. Introduction

If you want to use them, to set these speeds, please configure the dipswitch to S/W Config setting and use ParaniWIN or AT commands. Please refer to P

Página 8 - Note *:

Table 3-7 Pairing Process with other Bluetooth device by Pairing Button SD1 Status LED Other Bluetooth Device Status 1. Factory reset Mode0 Mode LED t

Página 9 - 2. Getting Started

Figure 3-3 Main Window Figure 3-4 Information Window Serial port settings can be changed by <Start Configuration> and <Parani

Página 10

Figure 3-5 Menu Bar at Upper Left corner of ParaniWIN When the ParaniWin software is able to access the Parani-SD1000U properly, the icons in the

Página 11 - 2.2.3. Virtual Serial Port

Parani-SD1000U has 4 response messages, „OK‟, „ERROR‟, „CONNECT‟, and „DISCONNECT‟. In some cases, these responses can affect the host syst

Página 12 - 3. Configuration

User Guide for the Parani-SD1000U Version 2.0.2 Firmware version 2.0.X Printed in Korea Copyright Copyright 2008~2012, Sena Technologies, Inc. All ri

Página 13 - 3.5. Hardware Flow Control

Figure 3-8 Signal Strength Test The signal strength test shows LInkQuality and RSSI values. The closer LinkQuality is to 255 and RSSI is to 0, thi

Página 14 - 3.7. Dipswitch

Figure 3-9 Connection (in) Window If the Connection Wizard icon is clicked, an easy to use pairing menu will appear: Figure 3-10 Connection Wiza

Página 15 - 3.8. Pairing Button

Step 1. Connect SD1 and then push the START button. Step 2. Disconnect SD1, connect SD2 and then push the Next button after setting up

Página 16 - 3.10. ParaniWIN

start>setting>control panel>add/remove programs. For more precise details on HyperTerminal installations, please refer to Microsoft W

Página 17

4. Multiple Connection Mode 4.1. Overview Parani-SD1000U supports multiple connections up to 4 slave units. There are two types of multiple connect

Página 18

4.2. Configuration All the slaves should be in the status of waiting for connection either in Mode 2 or Mode 3 and the master unit tries to connect

Página 19

4.3. AT Commands 4.3.1. AT+MULTI,n Select a multiple connection mode. Refer to Table 4-1 for descriptions. 4.3.2. AT+MLIST? It shows the current

Página 20

4.4. Notes When large data exchange occurs in Multi-drop mode without flow-control enabled, the master unit may experience data loss. It may also ex

Página 21

5. Approval Information 5.1. FCC FCC Part 15 Subpart C Section 15.247 FCC ID: S7APARANISD1000U 5.1.1. FCC Compliance Statement This device comp

Página 22 - 3.12. Terminal Program

6. RF Information 6.1. Radio Frequency Range 2.402~2.480GHz 6.2. Number of Frequency Channel 79 channels 6.3. Transmission Method FHSS (Frequ

Página 23

Revision History Revision Date Name Description V1.0.0 2010-11-05 JH Park Initial Writing V1.0.1 2011-01-04 JH Park Modify Working Distance V2.0.2 20

Página 24 - 4. Multiple Connection Mode

Appendix A: AT Commands A.1. Terminology A.1.1. AT Command AT command set is the HTin fact standardTH HTlanguageTH for controlling H TmodemsTH. Th

Página 25 - 4.2. Configuration

Symbols Meaning ASCII Code  Carriage return 0x0D  Line feed 0x0A  Carriage return + Line feed 112233445566 Bluetooth device address N or m One d

Página 26 - 4.3. AT Commands

A.3. Command Description A.3.1. ATZ Response  OK Purpose Software Reset Description This has the same effects as Powercycling the unit. This

Página 27 - 4.4. Notes

A.3.6. AT+BTINFO? Response  112233445566,DeviceName,Mode,Status,Auth,Encryp,FlowControl  OK Purpose Display Bluetooth settings Description The

Página 28 - 5. Approval Information

CURRENT MODE: MULTI-DROP MODE TASK1 – 000195000001 TASK2 – DISCONNECT TASK3 – DISCONNECT TASK4 – 000195000004 A.3.11. AT+BTMODE,n Response  OK P

Página 29 - 6. RF Information

Example AT+SETESC,42 A.3.15. ATO (ATOx, ATObdaddr) Response None Purpose Convert the operation status of „Standby‟ to „Connect‟ Description You ca

Página 30 - Appendix A: AT Commands

Example AT+BTSCAN,2,30 A.3.19. AT+BTSCAN112233445566,to Response  OK  CONNECT 112233445566 or  OK  ERROR Purpose Wait for connection by

Página 31 - A.2. Command Category

Description The current Bluetooth connection will be disconnected. It takes about Supervision Timeout(S37) to detect an abnormal disconnection such as

Página 32 - A.3. Command Description

Purpose Set authentication and data encryption Parameters Authentication=0: Inactivate (Default) Authentication=1: Activate Encryption=0: Inactivate (

Página 33 - A.3.10. AT+MLIST?

Description All parameters are stored at S-register in flash memory. These values are sustained until hardware reset. A.3.32. ATSnn?  Response  v

Página 34 - A.3.14. AT+SETESC,nn

Contents 1. Introduction 7 1.1. Overview ...

Página 35 - A.3.18. AT+BTSCAN,n,to

AT+BTSEC,Auth,Encr ◎ AT+BTLAST? ○ ○ AT+BTMODEn ◎ AT+BTNAME=”Name” ◎ AT+BTKEY=”nnnn” ◎ AT+BTINFO? ○ AT+BTLPM,n ◎ AT+BTSD? ○ ○ AT+BTCSD ◎

Página 36 - A.3.21. ATD112233445566

Appendix B: S-Register S-registers contain 52 parameters for the Parani-SD Series. These are stored in flash memory and the values will be saved unl

Página 37 - A.3.26. AT+BTFP,n

S11=1, Parani-SD allows for the escape sequence character. Whenever it is needed, the Connect status can be changed to Standby. B.7. S12: Clear Data

Página 38 - A.3.31. AT&V

* When 10 bytes data are sent every intercharacter timeout, they are sent separately by 10 bytes at the optimal value. If the intercharater tim

Página 39 - A.4. Command Validity

B.23. S48: Low Power Max Interval (default 5000) This is the max interval value to use low power mode, which is set to 5000 initially. (5000 x 625μse

Página 40

B.31. S59: Current Slave in Communication (default 0) This value shows the current slave number in communication. The value is automatically stored w

Página 41 - Appendix B: S-Register

Appendix C: Trouble Shooting C.1. No Data Transmission C.1.1. COM Port Settings Check whether the Baud rate of Parani-SD matches that of its host

Página 42

Appendix D: Parani-SD1000U mechanical drawing D.1. Parani-SD1000U mechanical drawing (mm)

Página 43

Appendix E: Warranty E.1. GENERAL WARRANTY POLICY Sena Technologies, Inc. (hereinafter referred to as SENA) warrants that the Product shall conform

Página 44

- Floods, lightning, earthquakes, - Water spills, - Replacement of parts due to normal wear and tear, - Hardware has been altered in any way, - Produc

Página 45

A.1.2. AT Response ... 30 A.1.3. Operati

Página 46 - Appendix C: Trouble Shooting

B.15. S28: Escape Sequence Character (default 43) ... 43 B.16. S31: Page Timeout (de

Página 47

1. Introduction 1.1. Overview Parani-SD1000U is a usb adapter for wireless serial communication using Bluetooth 2.0

Página 48 - Appendix E: Warranty

Diagnostic LED Mode, Connect, Serial Rx/Tx Environmental Operating temperature: -20 ~ 70 oC Storage temperature: -40 ~ 85 oC Humidity : 95% (Non-conde